Code AS 1735.5:2015 indicated in 5.5.3.4: ‘On escalators, the possibility of trapping between skirting and steps shall be minimized. For this purpose, installation of skirt deflectors shall be fulfilled’ And ‘For existing escalator, The minimum dimension permissible is 8 mm between the underside of the rigid part of the deflector device and the step nose line as per EN115-2:2010 5.5.3 (Rules for the improvement of safety of existing escalators and moving walks)’ In order to make the lift companies in Australia more easily accomplish the improvement of safety of existing escalators and moving walks, we have prepare the stocks of escalator safety brushes in Brisbane


  • Category: Escalator Parts

Description

Safety Application: 

Alerts passengers to keep a distance from the side skirts and prevent entrapment accidents.

Specification standard: 

Conforms to international standards and world escalator safety procedures, such as A17, EN17, B44, etc.

Easy installation: 

Brush can easily slip into aluminium alloy base which are customized for each unit for easy installation and maintenance.

Quality Material:

Well structured aluminium alloy base, Aluminium profile model:6063

Brush bristle with high flexibility, strong elasticity

Conforms to SAA (Australia), EN115:2008 (Europe), ANSI (America) and Cap 327 (Hong Kong)

Performance Parameters:

Anti-static 10^4 ~10^12 Ω.

Low temperature resistant – 40°C, high-temperature thermal.

Fire retardant filament FR-V0

Tensile resistance ≥6KG